piwik image

ABB XT1NE3050BFF000XXX
ABB

ABB XT1NE3050BFF000XXX

loading

XT1NE3050BFF000XXX

ABB XT1NE3050BFF000XXX Tmax XT Low Voltage Molded Case Circuit Breaker, 600Y/347/690 VAC, 50 A, 18 kA Interrupt, 3 Poles, Adjustable Thermal/Magnetic Trip

  • Item#: 702541
  • Mfr#: XT1NE3050BFF000XXX
  • UPC: 888614445260
  • Feature high specific let-through current peak and energy limiting characteristics that allow the circuits and equipment on the load side to be sized in optimum way
  • XTraordinary limiting characteristics allow savings in copper and footprint in switchboard, high selectivity values and very compact motor protection solutions high breaking capacity
  • A dedicated range of accessories and a renewed solution for electronic trip units to adapt Tmax XT to different applications scenarios installation flexibility
  • Specific electronic trip units for energy metering, motor protection and generator protection in addition to a Modbus communication module for integration in a supervision system
  • Wide range of keylocks and padlocking options, plug-in and withdrawable versions to speed up maintenance operations and improved diagnostic to have ready to use information about breakers status
  • Frame XT1 to 125A, 600Y/347 V (UL)/160 A, 690 V (IEC) thermal magnetic protection
  • F front terminals, no lugs installed on line and load side termination (top/bottom)
  • 18 kA normal breaking capacity
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • loading

DESCRIPTION

Tmax XT molded case circuit breakers guarantee an extremely high performance level while being progressively smaller in size, simple to install and able to provide increasingly better safety.

ABB Molded Case Circuit Breaker, Low Voltage, Series: Tmax XT, 600Y/347/690 VAC, 50 A, 50/60 Hz Frequency, 18 kA Interrupt, XT1 125A Frame, Adjustable Thermal/Magnetic Trip, 50 to 500 A Trip, 3 Pole, Front Line/Load Side Connection, Double Insulated Insulation, -13 to 158 deg F, 5.12 in H x 3 in W x 2.75 in D Dimensions

SPECIFICATIONS

Connection Type      :      Front Line/Load Side
Dimensions      :      5.12 in H x 3 in W x 2.75 in D
Frame      :      XT1 125A
Frequency Rating      :      50/60 Hz
Insulation Type      :      Double Insulated
Series      :      Tmax XT
Temperature Rating      :      -13 to 158 deg F
Trip Range      :      50 to 500 A
Type      :      Low Voltage
Voltage Rating      :      600Y/347/690 VAC
Amperage Rating      :      50 A
Interrupt Rating      :      18 kA
Number of Poles      :      3
Trip Type      :      Adjustable Thermal/Magnetic

DOCUMENTS

  • pdf
    Catalog
    https://www.purvisindustries.com//ASSETS/DOCUMENTS/ITEMS/EN/ABB_XT1BE3016BFF000XXX_Catalog.pdf
  • pdf
    Specification Sheet
    https://www.purvisindustries.com//ASSETS/DOCUMENTS/ITEMS/EN/ABB_XT1NE3050BFF000XXX_Datasheet.pdf